Head and jambs of finished frame shall be secured together with continuous weld.
Elevator door frame detail.
Applicable is not the responsibility of the elevator contractor.
Cs door protection is created using our award winning acrovyn 4000 wall protection.
Entrance wall and finished floor are not to be constructed until after door frames and sills are in place.
Counterbalanced vertical bi parting doors are recommended to provide the greatest fire protection.
Elevator entrance lift doors in detail elevator entrance is the topic in the post.
At that time the elevator car s door will be mechanically coupled to landing entrance so that both landing entrance door and car.
3 leg j track jamb anchor.
4 171 pass type doors 1 2 13 door frame projection 1 2 projection jamb extends to beam channel lintel channel jamb sill jamb and sill detail thyssenkrupp elevator has a wide choice of freight door options.
3 this capacity is not available with center opening doors.
Elevator car moves up and down and stops at the level.
The interface of the elevator wall with the hoistway entrance assembly shall be in strict compliance with the elevator contractor s requirements.
Fire rated door and frame.
Detail title date issued.
Selecting the appropriate door type and duty class for the intended purpose guarantees reliable and uninterrupted.
4 0 x 9 0 3 6 x 7 6.
Elevator service 5000 lb.
The 120 mm wide frame door is a practical and elegant solution.
Schindler 5500 elevator entrance entrance details.
The design of the lobby and elevator door must take into account both aesthetic and functional requirements.
Per section detail 1 1 2 drywall pressure anchor frames nail in face frames maximum jamb opening size.
11 05 13 1 2 fire shield c gypsum board 2 layers fire shield gypsum board 1 fire shield shaftliner elevator door jamb elevator door jamb for elevator doors 7 0 elevator door head for elevator doors 7 0 elevator door head 20 ga.
The frames are finished in the.
Schindler 5500 mrl elevator entrance details keywords.
These requirements apply to all fire rated doors frames and windows.
This part is called landing entrance.
Landing door frames frame types standard bolted welded hidden subframe landing frame dimensions door jamb width a header height b.
Elevator shaftwall head and jamb details scale.
For a 1588 kg capacity car with front and rear doors the doors must be in adjacent corners.
Capacity horizontal sliding center opening doors sd142100 03 dwg december 2008 none.
4 to meet the requirements of ibc code for 2134 mm stretchers a 1219 mm center opening for 1814 kg capacity only or 1067 mm side opening for 1588 kg or 1814 kg capacity door is required.