Fsae lobbies are not required to be enclosed at the levels of exit discharge.
Elevator fire door requirements.
Fsae requirements fire service access lobby o formed by 1 hr smoke barriers with smoke draft doors ultra high rises get impact resistant construction o direct access to stairway o 150 sf with a dimension not less than 8 ft standby power and.
Life safety code the international building code ibc and the international fire code ifc.
Fire rated door assemblies must meet the requirements of the applicable building or life safety code such as the national fire protection association nfpa 80.
For example nfpa 101 currently requires smoke leakage rated assemblies for new fire doors serving an area of refuge and requires compliance with nfpa 105 for new door assemblies in three locations.
Served by fire servic e access elevators complying with sections 3007 1 through 3007 9.
The minimum time for elevator doors to remain fully open in response to a car call is 3 seconds ada 4 10 8 space is provided for a wheelchair user to enter reach controls and exit the elevator car ada 4 10 8 door opening is at least 36 cab length is at least 51 with at least 54 from the back of the cab to the face of the door.
So as a building owner or manager it s imperative and the law that you test your elevator fire service monthly.
The elevator smoke and fire curtain comprises a flexible heat resistant material which is impervious to smoke and hot gases.
The syntégra elevator smoke door meets ul1784 has fire ratings available up to 3 hours is ada compliant and will ensure you meet all code requirements.
Standard for fire doors and other opening protectives nfpa 101.
A swing door mounted at an elevator opening and held open with a magnetic hold meets the fire and smoke partition code requirements but can be susceptible to tenant tampering and have an undesirable aesthetic effect in the space.
Fire curtain technologies distributes an architecturally pleasing solution to elevator smoke protection.
During a fire an elevator is a lifeline for people living on the upper floors.
For a clean code compliant and cost effective solution for your elevator smoke containment needs the syntégra door systems is the smart choice.
This rule does not apply to the hoistway doors elevator control room doors or elevator control space doors.
Vestibules that are part of a smokeproof enclosure horizontal exits and elevator lobby doors in occupant evacuation elevator shaft systems.